- Submit Request
- Campus Maps
- Directory of buildings
- Academic Quadrangle
- Alcan Aquatic Research Centre
- Applied Sciences Building
- Bee Research Building
- Beedie Field Concession
- Biology Trailer
- Blusson Hall
- Childcare Centre 1,2,3 &4 Office
- Convocation Mall
- Conerstone
- Diamond Alumni Centre
- Discovery 1
- Discovery 2
- East Concourse Cafeteria
- East Theatre Annex
- Education Building
- Facilities Services
- Fire Pump Station
- Greenhouses 1,2,3 & 5
- Halpern Centre
- High Voltage Substation
- Leslie & Gordon Diamond Family Auditorium
- LDC Stadium
- Lorne Davies Complex
- Maggie Benston Centre
- Robert C. Brown Hall
- Saywell Hall
- Service Station
- Shrum Science Centre Biology
- Shrum Science Centre Chemistry
- Shrum Science Centre Kinesiology
- Shrum Science Centre Physics
- South East Classroom Block
- South Sciences Building
- Science Research Annex
- Strand Hall
- Student Union Building
- Technology & Science Complex 1
- Technology & Science Complex 2
- The Water Tower Building
- Trottier Observatory
- Transportation Centre
- Transit Loop Building
- W.A.C. Bennett Library
- Water Tower
- West Mall Centre
- West Parkade
- Winter Operations Building
- Barbara Rae House
- Dining Commons
- Hamilton Hall
- Mctaggart Cowan Hall
- Pauline Jewett House
- Shadbolt House
- Shell House Residence
- Townhouses (Total 9 buildings)
- Residence Phase1 East
- Residence Phase1 West
- University-Childcare-Centre
- Building & Infrastructure Records
- Key Plans
- Mapping Services
- Directory of buildings
- Projects & Initiatives
- Construction Projects
- REDI Initiatives
- Sustainable Initiatives
- Health and Safety Initiatives
- Contractors
- ¶¡ÏãÔ°AV Owner's Technical Requirements
- Services
- Building Renovations, Renewals or Modernizations
- Building Signage Requests
- Confidential Shredding
- Custodial Services
- Event Setup
- Filming on Campus
- Furniture & Equipment Removal
- HVAC and Room Occupancy Schedule Changes
- Mail & Parcel Services
- Maintenance Requests
- Minor Building Alterations & Equipment Installations
- Moving Services
- Office Supplies
- Recycling Services
- Snow and Ice Removal Services
- Space Inventory Management
- Real Estate
- About
- Contact Us
- Senior Management Team
- Administration and Real Estate Services
- Campus Planning & Development
- Maintenance and Operations
- Awards & Achievements
- News
- Renovated Diamond Alumni Centre now open for bookings
- ¶¡ÏãÔ°AV unveils plans for new student housing and child care centre
- ¶¡ÏãÔ°AV School of Medicine moves forward
- Adjustments to cleaning services – What you need to know
- Flushing Repair Costs Down the Drain
- New improvements to tackle snow at ¶¡ÏãÔ°AV
- Engineer Breaks Down Gender Barriers and ¶¡ÏãÔ°AV's Energy Emissions
- One Small Change Leads to Sustainable Reduction in Paper Usage by 90 Per Cent for Important ¶¡ÏãÔ°AV Workflow
- Burnaby Campus Biomass Facility Celebrates 2nd Year Anniversary After Smashing Renewable Energy Records
Asbestos Management
An extensive Asbestos Survey has been conducted at ¶¡ÏãÔ°AV and a room-by-room hazard analysis was performed to determine the presence and risk, if any, of asbestos on campus. Although no immediate hazard existed, asbestos containing areas with a high potential for future disturbance have been removed and a long term Asbestos Management Program was approved by the Workers' Compensation Board of British Columbia.
Asbestos containing materials (ACM) on campus are primarily found in:
- Cementitious texture coatings on ceilings and as overspray above ceilings
- Fumehood linings and ductwork
- Floor tiles
- Building and underground piping systems
- Insulation on pipes, pipe elbows and boilers
- Asbestos board backing radiators
Warning: drywall and asbestos floor tiles are not labelled.
ACM Identification at ¶¡ÏãÔ°AV
Asbestos texture coatings and asbestos insulation areas are identified with either a red or black stylized "A" with a circular border, spaced at 15-foot intervals. Potentially, ACM areas missed by the survey, may not show the symbol. To prevent accidental disturbance of ACM, Facilities Management must be contacted before carrying out work to ensure that an area does not contain asbestos. Supervisors shall ensure that all personnel under their direction have taken appropriate training in asbestos identification and have been made aware of the possible presence of asbestos. When working in the vicinity of asbestos, workers must follow safe work procedures to ensure that ACM is not disturbed.
If anyone discovers asbestos containing material which has been disturbed, they must immediately leave the area and notify their supervisor. The Facilities Services Department must be notified of the disturbance and access to the area should be restricted until personnel from Facilities respond to the scene.
Asbestos on campus in its present condition poses no health threat to anyone as long as it is not disturbed (i.e. - drilled into, cut or sanded).
Asbestos contact numbers:
Facilities Management Service Desk: Local 778-782-3582
Environmental Health & Safety Office: Local 778-782-4978 or 778-782-3867